Section 4 Component Teardown
4-10
Removing the Condenser Fan and Blower
Assembly
The condenser fan and blower assembly consists of
the blower wheel, condenser fan and shroud, front and
rear blower housing and right bulkhead partition. The
assembly is secured with screws to the evaporator,
condenser and the unit base.
To remove the condenser fan and blower assembly:
1. Disconnect power supply from unit.
2. Remove the front panel assembly. Pull the unit from
the cabinet wrapper/sleeve.
3. Remove the front scroll cover. The wire leads from
the compressor, condenser fan and capacitor must
be disconnected from the control box components.
The control box must then be removed from the
unit.
4. Remove the capacitor cover. Disconnect wire leads
and remove from unit.
5. Cut wire retainers, then route the wire harness leads
so that the condenser fan assembly can be pulled
straight up out from the unit base.
6. Remove condenser fan cover.
7. Extract the two screws from each side securing the
fan assembly to the condenser assembly.
(See Figure 4-20)
8. Extract the two screws from the lower right side
securing the right bulkhead partition to the unit
base. (See Figure 4-20)
9. Extract the two screws from the right front securing
the right bulkhead partition to the evaporator.
(See Figure 4-21)
10. Extract the two screws from the left side securing
the right bulkhead partition to the unit base and the
evaporator.
11. Extract the two screws under the condenser fan
motor securing the assembly to the unit base.
(See Figure 4-20)
12. Pull condenser fan assembly straight up out from the
unit base.
Figure 4-20.
Figure 4-21.
Screws
Screws
Screws
Przeglądanie stron 69