14 installation electrolux integrated bbq 600/300mm
bench width 600 min
539
464
202
42
590
538
464
202 212
warning
• This appliance requires venting. An open area as
indicated below must be allowed for. A suitable grille
can be fitted if desired. This vent area is to allow air
into the enclosure for the correct combustion of gases
and for the correct exhausting of the products of
combustion. This vent must be 600mm x 25mm for
models EQBH60AS & EQBL60AS, and 300mm x 25mm
for model EQBL30AS. See location options on pg16.
Installing in a bench with a splashback
• The splashback must be made from a
non-combustible material.
• In the case of mounting this appliance against a wall
or fence it is imperative that care is taken to ensure
the isolation of combustible materials. All combustible
materials must be kept 450mm away from the barbecue.
• For roasting hood model there is a specic minimum
clearance required at the back of the barbecue between
the splashback and the bench cut-out of 73mm.
This is to allow clearance to open.
73 min to bench cut out
547
73 min to bench cut out
603
INTBBQ600/300_Jun11.indd 14 30/06/11 11:53 AM