32 electrolux
Electrical connection
The unit is preset to work with a voltage
of single phase 230 V.
Before making the connection make sure
that:
- the energy power available in the user's
house is sufficient for the normal supply
of this appliance (see rating plate).
- the unit is correctly connected to earth
through a suitable plug and according to
the installation country Laws.
- the socket or the omnipolar switch used
for the connection must be easilv reached
with the installed appliance.
The appliance is supplied with electric
cable, therefore you will have to fit it with a
standard plug, suitable for the total electric
load shown on the rating plate. The plug is
to be inserted into a suitable wall socket.
If you wish to directly connect to the
mains, you have to interpose an omnipolar
switch with a minimum opening between
flame is obtained.
• If changing from liquid gas to natural gas
20 mbar, undo the by-pass screw about
1/4 of a turn, until a small regular flame
is obtained.
• If changing from natural gas 20 mbar
to natural gas 13 mbar undo the by-
pass screw about 1/4 of a turn, until a
small regular flame is obtained.
• If changing from liquid gas to natural gas
13 mbar, undo the by-pass screw about
3/4 of a turn, until a small regular flame
is obtained.
Reassemble the parts following the same
procedure backwards.
Finally, check the flame does not go out
when quickly turning the knob from the
maximum position to the minimum position.
by-pass screw
contacts of 3 mm, between the unit and the
mains, complying with the existing
regulations.
The brown live wire (originating from the
clamp of the appliance junction box) must
always be connected to the phase of the
mains supply. In any case, the supply cord
must be positioned in such a way as it does
not reach in any point a temperature higher
by 50°C than the room temperature.
Replacement of the electric cable
The replacement of electric cable
must be carried out exclusively
by the service force centre or by
personnel with similar
competencies, in accordance
with the current regulations.
Should the supply cord need to be
replaced, use only the following cable types:
H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F. It is
necessary that the yellow/green earth wire is