Electrolux EKG613A1OX Instrukcja Użytkownika Strona 22

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 21
Natural Gas: G20 (2H) 20 mbar
14.4 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Oven 50
Grill 59
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0 0.75 119
Semi-rapid 2.0 0.45 96
Auxiliary 1.0 0.35 70
Oven 2.5 1.0 104
Grill 2.4 1.5 104
14.6 Gas burners for LPG G30 28-30 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 2.5 1.0 75
Grill 2.4 1.5 75
14.7 Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
www.electrolux.com22
Przeglądanie stron 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28

Komentarze do niniejszej Instrukcji

Brak uwag