9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 3,8 1,4 146
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
1/100 mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
3,8 1,4 98 276 271
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGS9353NOX
Type of hob Built-in hob
Number of gas burners 5
Energy efficiency per gas burner
(EE gas burner)
Left middle - Triple Crown 54.3%
Centre rear - Semi-rapid 60.0%
Right rear - Semi-rapid 60.0%
Centre front - Auxiliary not applicable
Right front - Semi-rapid 63.2%
Energy efficiency for the gas hob
(EE gas hob)
59.4%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of energy
- General
10.2 Energy saving
Before use, make sure that the burners and pan supports are assembled correctly.
Use cookware with diameters applicable to the size of burners.
Center the pot on the burner.
When you heat up water, use only the amount you need.
If it is possible, always put the lids on the cookware.
When the liquid starts to boil, turn down the flame to barely simmer the liquid.