9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 5,6 kW
Gas replacement: G30/G31 (3B/P) 30/30 mbar = 407 g/h
Electric zones: 1,8 kW
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2H3B/P
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 2,7 0,75 130
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Rapid 2,7 0,75 86 196
Semi-rapid 1,9 0,45 71 138
Auxiliary 1,0 0,33 50 73
9.6 Electric cooking zones specification
Cooking zone
Nominal Power (Max heat set‐
ting) [W]
Cooking zone diameter [mm]
Left rear 1800 180
For optimal cooking results use
cookware not larger than the diameter of
the cooking zone.
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGE6182NOK
ENGLISH 35