1. Remove the electrical control board
cover from the outdoor unit by
loosening the screw.
2. Connect the connective cables to the
terminals as identified with their
respective matched numbers on the
terminal block of indoor and outdoor
units.
3. Secure the cable onto the control
board with the cord clamp.
4. To prevent the ingress of water, form a
loop of the connective cable as
illustrated in the installation diagram of
indoor and outdoor units.
5. Insulate unused cords (conductors)
with PVC-tape. Process them so they
do not touch any electrical or metal
parts.
Connect the cable to the outdoor unit
Screw
Cover
23 electrolux electrical work
OPERATION
This lamp illuminates when the air
conditioner is in operation.
TIMER
Lights up during Timer operation.
DEFROST indication lamp
(Enabled on cooling & heating
models only): Lights up when the
air conditioner starts defrosting
automatically or when the warm air
control feature is activated in
heating operation.
Temperature indicator
Displays the temperature settings
when the air conditioner is
operational. Displays the
malfunction code.
Signal receiver
1
2
3
5
3
1
2 5
The description in the control is based
on a typical model. The functions are
the same in your air conditioner, even if
there are some differences in the
appearance.
Display panel
(indoor unit)
1
4
2
3
product description electrolux 32