Connection via Min. size Cable/
flex
Cable/flex type Fuse
Cooker Control
Circuit
2,5 mm² PVC/PVC twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a mini-
mum gap of 3 mm between the switch
contacts and of a type suitable for the
required load in compliance with the cur-
rent regulations.
The switch must not break the yellow
and green earth cable at any point.
After installation and connecting,
the cable must be placed so that it
cannot at any point reach a
temperature of more than 50°C
above the ambient temperature.
Before the oven is connected, check
that the main fuse and the domestic
installation can support the load;
and that the power supply is
properly earthed.
The manufacturer declines any
responsibility should these safety
measures not be carried out.
Installation
IMPORTANT
The new appliance may only be in-
stalled and connected by a qualified
installation engineer.
Please comply with this instruction.
If you do not, any damage resulting
is not covered by the warranty.
Safety information for the installer
The set-up of the electrical installation
is arranged so that the appliance can
be isolated from the mains with a mini-
mum 3 mm all-pole contact separa-
tion.
Suitable isolation devices include, for
example, circuit breakers, fuses
(screw type fuses are to be removed
from the holder), RCDs and contac-
tors.
Anti-shock protection must be provi-
ded by the installation.
The built-in unit must meet the stability
requirements of DIN 68930.