TECHNICAL DATA
Hob dimensions
Width: 744 mm
Length: 510 mm
Hob recess dimensions
Width: 560 mm
Length: 480 mm
Heat input
Triple Crown burner: 4.0 kW
Rapid burner: 3.0 kW
Semi-rapid burner: 2.0 kW
Auxiliary burner: 1.0 kW
TOTAL POWER: G20(2H) 20mbar = 12
kW
G30 (3+) 28-30 mbar
= 858 g/h
G31 (3+) 37 mbar =
843 g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible cable
with non rewirable
plug fitted with a 3
amp cartridge fuse
Category: II2H3+
Gas connection: G 1/2"
Gas supply: G20 (2H) 20 mbar
Appliance class: 3
By-pass diameters
Burner Ø By-pass in 1/100
mm
Auxiliary 28
Semi-rapid 32
Rapid 42
Triple Crown 56
Gas burners
BURNER
NORMAL
POWER
RE-
DUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3+)
28-30/37 mbar
kW kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30
28–30
mbar
G31
37 mbar
g/h g/h
Auxiliary 1.0 0.33 70 0.095 50 73 71
Semi-rap-
id
2.0 0.45 96 0.190 71 145 143
Rapid
3.0 (natural
gas)
2.8 (LPG)
0.75 119 0.286 86 204 200
Triple
Crown
4.0 1.4 146 0.381 98 291 286
ENVIRONMENT CONCERNS
The symbol on the product or on its
packaging indicates that this product may
not be treated as household waste. Instead
it should be taken to the appropriate
collection point for the recycling of electrical
and electronic equipment. By ensuring this
product is disposed of correctly, you will
help prevent potential negative
consequences for the environment and
human health, which could otherwise be
caused by inappropriate waste handling of
this product. For more detailed information
12 electrolux