4.2 Contact switch and input electronics (UI)
The contact switch is glued directly on the glass ceramic and over a foil conductor connected
with input electronics. The UI is fixed in a plastic framework, which is also glued directly onto on
the glass ceramic.
Fig. 1 Fig. 2
The trough framework is screwed onto the trough bath with star Torx TX20 screws. Before the
glass ceramic can be removed after the complete loosening of the star screws, it must be lightly
raised at the front, so that both 3-pole connection cable input electronics/ induction module can
be taken off (fig. 1).
Fig. 3
Input electronics are configured and provided with a standard software. After extracting from the
holding frame and taking the foil conductor off input electronics can be removed.