8.8 Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 150 mm
30 mm
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.9 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 595 mm
Depth 525 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
Semi-rapid 32
Auxiliary 28
ENGLISH