9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 590 mm
Depth 520 mm
9.2 Other technical data
TOTAL POWER: Gas original: G30/G31 (3B/P) 30/30 mbar = 498 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: I3B/P
Gas connection: G 1/2"
Appliance class: 3
9.3 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 45
Semi-rapid 35
Auxiliary 28
9.4 Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 2,45 0,81 178
Semi-rapid 1,7 0,56 65 124
Auxiliary 1,0 0,33 50 73
10. ENVIRONMENT CONCERNS
Recycle the materials with the symbol
. Put the packaging in applicable
containers to recycle it. Help protect the
environment and human health and to
recycle waste of electrical and electronic
appliances. Do not dispose appliances
marked with the symbol with the
household waste. Return the product to
your local recycling facility or contact
your municipal office.
ENGLISH 15