BURNER Ø BYPASS 1/100 mm
Auxiliary 28
9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar 8 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar 567 g/h
G31 (3+) 37 mbar 557 g/h
Electric sup‐
ply:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car‐
tridge fuse
Appliance cat‐
egory:
II2H3+
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
WARNING!
This appliance does not
function with the existing gas
settings if installed in Malta.
Therefore, before connecting
the appliance it is essential
to change the nozzles
according to the type of gas
used according to the table
below.