Installation Instructions
102
Electrical Connection
Only the supply lead fitted on the recess may be used for connecting
the unit. Replacement cables can only be obtained from your local AEG
Service Centre.
A fixture must be provided in the electrical installation which allows
the appliance to be disconnected from the mains at all poles with a
contact opening width of at least 3 millimetres. Suitable isolation
devices include, e.g. cut-outs, fuses (screw type fuses are to be removed
from the holder), earth leakage trips and contactors.
1
Attention! Make the electrical connection in accordance with the con-
nection diagram.